6400 SERIES Precision Component Analyzer

6400 SERIES

specyfikacja

Overview

The 6430B and 6440B Precision Component Analyzers provide thorough and accurate testing of any passive component to high resolution. In particular, for capacitor manufacturers, the instruments provide capabilities for both fast automatic production testing and complete design characterisation. Users include designers of passive components, manufacturing test, designing and testing materials as well as circuit designers who are evaluating component characteristics.

The resonant frequency can be automatically calculated for any component together with its equivalent series or parallel circuit at that frequency. Both instruments are designed for high performance testing of components, with a basic accuracy of 0.02%, at a low price. 6430B is the entry level instrument covering to 500 kHz whilst the fully featured 6440B covers to 3 MHz.

To evaluate a component performance at high speed over a specified range of frequencies, multi frequency mode is used. In this mode the operator decides which parameter is to be measured and at what frequencies. The 6430B and 6440B does the rest, creating an easy to read table on the large LCD display. Each test can have a simple Pass/Fail display.

Fast automatic multi-frequency production testing of capacitors

The 6430B and 6440B deliver fast automatic testing of capacitors in a production environment. The user is able to select measurements from any of the instruments range and perform up to eight different tests on each component. Tolerance bins can be selected for each of the tests. The instrument selects the overall bin after completing all the tests. The measured results can be output over the GPIB or to a printer. The test sequence is triggered by external input, GPIB or the front panel. Once the test sequence is complete the bin is selected and the measured data is made available on the GPIB. This process takes place at very high speed allowing a dual frequency test to be completed in approximately 180 ms. Pass/Fail data in statistical form is available to the user and can be viewed on the LCD display, printed to a local printer or exported over the GPIB.

  
  

Protection against charged capacitors

High precision measuring instruments can be sensitive to charged capacitors and if connected can lead to costly repairs and unacceptable downtime. Wayne Kerr Electronics have identified this problem and developed a solution that protects the test equipment from charged capacitors. In this event, the protection unit blows fuses, which can be easily and cheaply replaced, whilst the test equipment remains unharmed and continues to provide reliable accurate performance. The protection unit will protect the test equipment from up to 25 Joules of charged energy.

 
Overload Protection Unit 1J1100

Key Features

  • Fast automatic capacitor testing
  • High measurement accuracy on dissipation factor
  • Fast measurement speed
  • 0.02% basic measurement adccuracy
  • Comprehensive measurement functions, Graphical sweep on all measurement functions
  • Characterize components to 3 MHz
  • Large LCD Display and intuitive user interface
  • Unbeatable price

Technical Specification

Measurement Function Any of the following parameters can be measured and displayed:
Inductance (L), impedance (Z), DC resistance (Rdc) and capacitance (C)
Series or Parallel Equivalent Circuit C+R, C+D, C+Q, L+R, L+Q
Series equivalent circuit only X+R, X+D, X+Q
Parallel equivalent circuit only C+G, B+G, B+D, B+Q
Polar Form Z + Phase Angle, Y + Phase Angle
Frequency Range 6430B - 20 Hz to 500 kHz > 1000 steps ( > 1500 steps with analysis option fitted)
6440B - 20 Hz to 3 MHz > 1800 steps
Drive Level(Rdc) 100 mV or 1 V with 100 Ω source resistance
Internal DC Bias Supply 2 V with rapid charge capacitor bias
DC Bias Voltage (External) External supply of up to ±60 V may be connected via rear panel
Measurement Speeds 4 speeds selectable 
Up to 20 measurements per second for test frequencies ≧100 Hz
Measurement Ranges R, Z 0.01 mΩ to > 2 GΩ
G, Y 1 nS to > 2 kS
L 0.1 nH to > 2 kH
C 1 fF to > 1 F
D 0.00001 to >1000
Q 0.00001 to >1000
Rdc 0.1 mΩ to > 10 MΩ
Accuracy L/C ±0.05%
R ±0.02%
Q ± 0.05 %(Q + 1/Q)
D ±0.0002(1+ D2)
Rdc ± 0.1%

Accuracy varies with component range measurement speed and frequency
Input Specification Power supply 230 V AC ±10% or 115 V AC ±10% (selectable) 
Mains frequency 50/60 Hz
150VA maximum consumption
Display High contrast monochrome LCD 320 x 240 dot with CFL back lighting
Visible area 115 x 86mm
Viewing angle 45°
Measurement Connections 4 front panel BNC sockets
4-wire (Kelvin) measurements with screen at ground potential

6500B SERIA
6500B SERIA
Precyzyjne pomiary wysokiej częstotliwości w połączeniu z łatwym w użyciu interfejsem graficznym i kolorowym wyświetlaczem o wysokiej rozdzielczości. Wszystkie analizatory mają podstawową dokładność 0,05%, minimalną częstotliwość 5 MHz i maksymalną częstotliwość do 120 MHz w zależności od modelu.
6500P SERIES
6500P SERIES
The 6500P series of high frequency LCR meters include extended test frequency capability, high accuracy and a large high resolution color display
6565 SERIES
6565 SERIES
To evaluate components at currents up to 60 A, the 6565 DC Bias Units are used with the Wayne Kerr 6500B and 6500p models of precision analyzers
4300 SERIES
4300 SERIES
A range of easy to use LCR meters with comprehensive measurement functions.
Accurate and fast measurements may be made from 20Hz to 1MHz (43100) making the 4300 series the ideal choice for many applications in the test or production environment
3265B SERIES
3265B SERIES
To evaluate components at high currents the 3265B/25A DC Bias Units may be used with either the Wayne Kerr 3255B Inductance Analyzer or the 3260B Precision Magnetics Analyzer. Bias current may be set from 25mA to 25A in steps of 25mA
3260B SERIES
3260B SERIES
Offers all measurement parameters needed for the analysis of magnetic components up to 3MHz including true 4-terminal primary to secondary parameters by using 8 front panel BNC
3255B SERIES
3255B SERIES
Highly versatile and accurate inductance analyzers able to characterise devices in a clear and simple manner
1EV1006
1EV1006
Remote test fixture for axial, radial or bandoliered components. Complete with cable terminating in four BNC connectors
1EV1505
1EV1505
600 mm extension cable terminated with four BNC connectors at the instrument end and four individual crocodile clips at the component end.
1EV1905A
1EV1905A
The 1905A ead with two sprung needle probes is used to access surface mounted devices on circuit boards and for interfacing to hybrid components and chip components on tape.
1EV1905X
1EV1905X
The 1905X is a 4-2 BNC converter plus lead with two sprung needle probes to access surface mounted devices on circuit boards and for interfacing to hybrid components and chip components on tape.
1EVA40100
1EVA40100
Wayne Kerr Kelvin Clips consist of a 0.6 m cable assembly terminated with four BNC connectors at the analyzer end and a pair of 4-terminal Kelvin clips at the Device Under Test end.
1EVA40120
1EVA40120
Chip component tweezers for contacting leadless devices. The cable is terminated with BNC connectors.
1EVA40150
1EVA40150
The 40150 is a price sensitive version of 1EVA40100 Fine Jaw Kelvin Clips for use with 4300 series LCR Meters
1EVA40180
1EVA40180
600mm extension cable terminated with four BNC connectors at the instrument end and a pair of large jawed Kelvin clips at the component end.
1J1012 SMD 2
1J1012 SMD 2
The 1012 fixture makes a 2-terminal measurement to end contact surface mount devices and is suitable for medium and high impedance devices.
1J1014 SMD 4
1J1014 SMD 4
The 1014 fixture makes a 4-terminal measurement to end contact surface mount devices and is especially suitable for low impedance devices.
1J1020
1J1020
The 1020 Fixture is used with the 6500 series, and when used with the /K Materials Test firmware option allows the permittivity of the Material Under Test (MUT) to be calculated automatically.It allows both the Contacting Electrode and the Non-contacting Electrode Methods to be used up to a maximum frequency of 30 MHz.
1J1023
1J1023
The 1023 adaptor allows 2-terminal accessories to be used with 4-terminal analyzers, such as the 4300 and 6500, which do not have a 2 Term/ 4 Term switching facility on their front panel.
1J1100
1J1100
The 1100 Protection Unit is designed for use with the 6430B or 6440B Component Analyzers and provides protection up to 25 Joules of energy.
1J10324
1J10324
The 10324 fixture makes a 4-terminal measurement to bottom contact surface mount devices and is especially suitable for low impedance devices.
FACTORY VIEW
FACTORY VIEW
MESCO VIEW
MESCO VIEW

Wayne Kerr Electronics jest producentem precyzyjnych urządzeń pomiarowych, uznanym za lidera w swojej dziedzinie i rozpoznawanym za jakość, dokładność i szerokie możliwości swoich urządzeń. Wayne Kerr rozpoczął działalność w roku 1946, w Londynie w Wielkiej Brytanii. W ciągu ostatnich 60 lat firma Wayne Kerr Electronics stała się wiodącym producentem urządzeń do procesów testowych (mierniki LCR, analizatory impedancji, wysokiej częstotliwości analizatory LCR). Zapewnia wsparcie techniczne i serwis swoich urządzeń klientom na całym świecie. W celu usprawnienia obsługi i wsparcia technicznego na polskim rynku firma Wayne Kerr Electronics utworzyła autoryzowany oddział firmy. Poza tym posiada swoje oddziłay na całym swiecie, w kilku krajach Europy, w Stanach Zjednoczonych, Singapurze, Indiach, Japonii, Chinach i na Tajwanie.