close
loading
produkt

6500P SERIES High Frequency LCR Meter

6500P SERIES

specyfikacja

Accuracy and versatility makes the 6500P Series HF LCR Meters the ideal choice for many different tasks and applications in manufacturing and test. The wide range of frequency specifications means that a model can be selected that best meets application requirements and within budget.

High measurement accuracy

Capacitance, inductance and impedance basic accuracy is an excellent ±0.05%. Dissipation factor accuracy is ±0.0005 and the quality factor accuracy is ±0.05%.

Variable drive and bias levels

AC drive levels up to 1V or 20mA can be selected to evaluate components in realistic operating environments.

The /D1 DC bias option provides 0 to +40V dc bias voltage and 0 to +100mA dc bias current while the /D2 option provides -40V to +40V dc bias voltage.

External control

The GPIB interface is used to control the instrument and read back measured values for applications such as quality control or for archiving purposes.

An Ethernet interface similarly allows the instrument to be controlled and to send out data - allowing it to be integrated into many test environments.

Wide range of interfaces

An external monitor or projector may be connected to the instrument. The ability to provide a large screen display is invaluable in production environments or for teaching and training.

Instrument control from both a keyboard and mouse is available. Any keyboard or mouse, with either PS/2 or USB interfaces, can be simply connected to provide an alternative method of instrument control and operation.

Data storage and retrieval

All measurement and setup data can be stored using the Ethernet interface or a USB flash memory (supplied as standard).

Setup data

Up to 20 instrument setups may be stored locally for each mode.

Bin handling

The /B1 option (non-isolated 5V) or /B2 option (isolated 24V) signals are available through a 25-way D-type connector. 10 bins can be set using absolute or percentage limits.

Printer outputs

Hard copy printouts can be obtained in a number of ways including direct to an HP-PCL compatible graphics printer or Epson compatible text/ticket printer. A networked HP-PCL compatible printer may also be used via Ethernet connection.

Component connections

Four front panel BNC connectors permit three or four terminal connections with the screens at ground potential.

The 1J1011 component fixture, supplied as standard, ensures optimum performance when measuring a wide range of components of leaded components and devices.

1J1012 (2 Terminal) and 1J1014 (4 Terminal) fixtures allow connection to surface mount devices.

Protection against charged capacitors

High precision measuring instruments can be damaged by charged capacitors which can cause costly repairs and unacceptable downtime. All the models in the range incorporate protection against charged capacitors.

Comprehensive and precise component tests at higher frequencies

The 6500P series capabilities are best summarised by "Comprehensive and precise component tests at higher frequencies". The instruments are the perfect solution for those who have demanding component measurement needs.

Key Features

  • Precise high frequency impedance measurements
  • Characterize components from 20 to 120 MHz
  • Wide range of models with maximum frequencies from 5MHz (6505P) to 120MHz (65120P)
  • 0.05% basic measurement accuracy
  • Comprehensive measurement functions
  • 0 to +40V DC bias voltage and 0 to 100mA DC bias Current (Option)
  • ±40V DC bias voltage (Option)
  • Easy to use with large TFT touch screen
  • Clear graphic displays aids measurements
  • Resonance Search
  • Intuitive user interface
  • Fully programmable over GPIB
  • Keyboard and mouse optional control
  • Competitively priced

Technical Specification

Measurement Function Capacitance (C) 
Inductance (L)
Resistance (R)
Reactance (X)
Conductance (G)
Susceptance (B)
Dissipation Factor (D)
Quality Factor (Q)
Impedance (Z)
Admittance (Y)
Phase Angle (Ø)
Frequency Range 6505P 20Hz to 5MHz
6510P 20Hz to 10MHz
6515P 20Hz to 15MHz
6520P 20Hz to 20MHz
6530P 20Hz to 30MHz
6550P 20Hz to 50MHz
65120P 20Hz to 120MHz

Frequency step size <1 mHz
Accuracy of set frequency ±0.005"%
AC Drive Level 10 mV or 1V rms (varies with frequency)
200 µA to 20 mA rms (varies with frequency)
Measurement Speeds 4 speeds selectable 
Up to 20 measurements per second for test frequencies ≧100 Hz
Accuracy Dissipation factor - ±0.0005 (1+D2)
Quality factor - ±0.05 %( Q+1/Q)
Capacitance / Inductance / Impedance - ±0.05%
Accuracy varies with frequency, drive level and measured impedance
DC Bias Current (Option) /D1 0 to +100mA dc bias current and 0 to +40V dc bias voltage 
/D2 -40V to +40V dc bias voltage
Binning (Option) 10 bins with absolute and percentage limits 
25 way d-type interface connector
/B1 (Non-isolated) Comon 0V Bin outputs 0 to 5V(normal) with >10mA current sink capability
/B2 (isolated) Comon 24V input outputs 0 to 24V with >10mA current source capability
Input Specification Power supply - Input voltage 90 V AC to 264 V AC (Autoranging)
Mains frequency 47 to 63 Hz
Display 8.4" VGA (650 x 480) color TFT with touch panel
Measurement Connections Four front panel BNC connectors permit two, three or four terminal connections with the screens at ground potential.
1J1011 Component Fixture (supplied as standard) allows connection to leaded components and devices. 
1J1012 (2 Terminal) and 1J1014 (4 Terminal) fixtures allow connection to surface mount devices.
Printer HP-PCL compatible graphics printing (local and network) 
Centronics / parallel printer port, Epson compatible text/ticket printing (local)
Remote Trigger Rear panel BNC with internal pull-up, operates on logic low or contact closure
GPIB Interface External instrument control 24 pin IEEE 488 connector
USB Interface Two Unversal Serial Bus (USB) interfaces
USB 1.1 compliant
VGA Interface 15-way D-type connector to drive an external monitor in addition to the internal screen
Network Interface 10/100-BASETX Ethernet controller
RJ45 connector
Keyboard Interface Standard USB or PS/2 keyboard port. Instrument front panel remains active with keyboard plugged in
Mouse Interface Standard USB or PS/2 mouse port
Touch screen remains enabled when the mouse is connected

6500B SERIA
6500B SERIA
Precyzyjne pomiary wysokiej częstotliwości w połączeniu z łatwym w użyciu interfejsem graficznym i kolorowym wyświetlaczem o wysokiej rozdzielczości. Wszystkie analizatory mają podstawową dokładność 0,05%, minimalną częstotliwość 5 MHz i maksymalną częstotliwość do 120 MHz w zależności od modelu.
6565 SERIES
6565 SERIES
To evaluate components at currents up to 60 A, the 6565 DC Bias Units are used with the Wayne Kerr 6500B and 6500p models of precision analyzers
6400 SERIES
6400 SERIES
Provide thorough and accurate testing of any passive component to market-leading accuracy
4300 SERIES
4300 SERIES
A range of easy to use LCR meters with comprehensive measurement functions.
Accurate and fast measurements may be made from 20Hz to 1MHz (43100) making the 4300 series the ideal choice for many applications in the test or production environment
3265B SERIES
3265B SERIES
To evaluate components at high currents the 3265B/25A DC Bias Units may be used with either the Wayne Kerr 3255B Inductance Analyzer or the 3260B Precision Magnetics Analyzer. Bias current may be set from 25mA to 25A in steps of 25mA
3260B SERIES
3260B SERIES
Offers all measurement parameters needed for the analysis of magnetic components up to 3MHz including true 4-terminal primary to secondary parameters by using 8 front panel BNC
3255B SERIES
3255B SERIES
Highly versatile and accurate inductance analyzers able to characterise devices in a clear and simple manner
1J1026
1J1026
The 1026 fixture is used with 6565 dc bias units to mount conventional DIL devices for testing up to 20A
1J1027
1J1027
The 1027 fixture is used with 6565 dc bias units to mount conventional DIL devices for testing up to 40A
1J1028
1J1028
The 1028 fixture is used with 6565 dc bias units to mount conventional DIL devices for testing up to 60A
1J1031
1J1031
The 1031 adaptor is used with 1026, 1027 or 1028 fixtures to allow 2-terminal connections to bottom contact surface mount devices for testing up to 60A.
1J1037
1J1037
The 1037 Adaptor provides SMA interface connectivity from a 6565 to a remote test head, such as a SMD taping machine
1J10264
1J10264
The 10264 fixture is used with 6565 dc bias units to allow 4-terminal connections to bottom contact surface mount devices for testing up to 20A
1J10284
1J10284
The 10284 fixture is used with 6565 dc bias units to allow 4-terminal connections to bottom contact surface mount devices for testing up to 60A
FACTORY VIEW
FACTORY VIEW
MESCO VIEW
MESCO VIEW

Wayne Kerr Electronics jest producentem precyzyjnych urządzeń pomiarowych, uznanym za lidera w swojej dziedzinie i rozpoznawanym za jakość, dokładność i szerokie możliwości swoich urządzeń. Wayne Kerr rozpoczął działalność w roku 1946, w Londynie w Wielkiej Brytanii. W ciągu ostatnich 60 lat firma Wayne Kerr Electronics stała się wiodącym producentem urządzeń do procesów testowych (mierniki LCR, analizatory impedancji, wysokiej częstotliwości analizatory LCR). Zapewnia wsparcie techniczne i serwis swoich urządzeń klientom na całym świecie. W celu usprawnienia obsługi i wsparcia technicznego na polskim rynku firma Wayne Kerr Electronics utworzyła autoryzowany oddział firmy. Poza tym posiada swoje oddziłay na całym swiecie, w kilku krajach Europy, w Stanach Zjednoczonych, Singapurze, Indiach, Japonii, Chinach i na Tajwanie.