6565 SERIES High Frequency DC Bias

6565 SERIES

specyfikacja

Overview

The 6565 HF DC Bias Unit is intended to be used with a Wayne Kerr 6500 analyzer, either the 6500B Precision Impedance Analyzer or the 6500P HF LCR Meter. Its function is to provide a source of DC bias current through the Device Under Test (DUT) while the analyzer is making AC measurements. Each 6565 unit can provide up to 10 A of DC current, and up to six 6565 units can be connected in parallel to supply a maximum 60 A. A digital ammeter on the front panel allows the user to see the dc bias current value and an indicator LED shows when the bias current is enabled.

High current 50Ω coaxial cable is used to carry the DC bias current from the 6565 unit to the fixture. The measurement signal from the 6500 analyzer front panel is connected to the fixture using a dedicated cable, a control cable connects the rear panels of the 6500 and 6565, and a safety interlock cable is connected from the fixture to the rear panel of the 6565.

There are 3 models in the 6565 series. The models are defined by their frequency range as follows:

           6565-05             20 Hz to 5 MHz

           6565-30             20 Hz to 30 MHz

           6565-120           20 Hz to 120 MHz

 

Any 6500 analyzer can be used with any 6565 unit. The maximum measurement frequency of the system will be determined by the instrument with the lower maximum frequency. For example, a 120 MHz 65120P used with a 5 MHz 6565-05 will have a maximum measurement frequency of 5 MHz

The 6500 analyzer controls the 6565 unit. The DC bias current is set as part of the 6500's measurement setup and the 6565's status and warning messages are shown on the 6500's display.

A common wound component measurement with the 6500B/6565 system is to measure the value of inductance as the DC Bias Current through the DUT is swept from 0A to the DUT's rated maximum current.

Another common technique is to use the Reference Trace function on the 6500B Precision Component Analyzer. This allows frequencies sweeps performed at different DC bias current levels to be instantly displayed and compared on the 6500B's display, as shown in the example screenshot below.

Frequency sweeps for Impedance and Phase Angle for 0 A and 10 A DC Bias Current

 

Key Features

  • No comparable system is currently available from other manufacturers
  • Allows measurements up to 120 MHz to be made with 40 A DC Bias Current flowing through the Device Under Test
  • Measurements up to 15 MHz can be made with 60A DC Bias Current
  • 6500B analyzer allows measurements to be made while sweeping DC Bias Current in value
  • Frequency swept measurements with different DC Bias Currents can be compared using the 6500B Reference Trace facility
  • Wayne Kerr fixtures provide a safety interlock circuit and other protection circuits to protect both the operator and the equipment under fault conditions 

Technical Specification

Measurement Function The 6565 series of DC bias units must be used in conjunction with either the 6500B Precision Impedance Analyzer or the 6500P HF LCR Meter.
Frequency Range 6565-05 20 Hz to 5 MHz 
6565-30 20 Hz to 30 MHz 
6565-120 20 Hz to 120MHz
Compliance Voltage 9V maximum at 1 V ac drive level
10V maximum at 0.25 V ac drive level
Basic Accuracy ±1%, Varies with measurement speed, frequency and options chosen.
Measurement Fixtures 1026 is applicable for currents up to 20 A and the 1027 for currents up to 40 A. For SMD use the 1031 adaptor must be used in addition to the selected 1026 or 1027
Input Specification Universal 85 to 265 V AC, 47 to 63 Hz 
Input current 4.2 A rms max. 
Power factor Meets EN61000-3-2 
Unit powers up automatically when connected to a powered
analyzer. Isolating switch provided
Measurement Connections I2C bus link controls application of DC current and monitors status of analyzer. Status data includes excessive voltage drop and over temperature 

6500B SERIA
6500B SERIA
Precyzyjne pomiary wysokiej częstotliwości w połączeniu z łatwym w użyciu interfejsem graficznym i kolorowym wyświetlaczem o wysokiej rozdzielczości. Wszystkie analizatory mają podstawową dokładność 0,05%, minimalną częstotliwość 5 MHz i maksymalną częstotliwość do 120 MHz w zależności od modelu.
6500P SERIES
6500P SERIES
The 6500P series of high frequency LCR meters include extended test frequency capability, high accuracy and a large high resolution color display
6400 SERIES
6400 SERIES
Provide thorough and accurate testing of any passive component to market-leading accuracy
4300 SERIES
4300 SERIES
A range of easy to use LCR meters with comprehensive measurement functions.
Accurate and fast measurements may be made from 20Hz to 1MHz (43100) making the 4300 series the ideal choice for many applications in the test or production environment
3265B SERIES
3265B SERIES
To evaluate components at high currents the 3265B/25A DC Bias Units may be used with either the Wayne Kerr 3255B Inductance Analyzer or the 3260B Precision Magnetics Analyzer. Bias current may be set from 25mA to 25A in steps of 25mA
3260B SERIES
3260B SERIES
Offers all measurement parameters needed for the analysis of magnetic components up to 3MHz including true 4-terminal primary to secondary parameters by using 8 front panel BNC
3255B SERIES
3255B SERIES
Highly versatile and accurate inductance analyzers able to characterise devices in a clear and simple manner
1J1026
1J1026
The 1026 fixture is used with 6565 dc bias units to mount conventional DIL devices for testing up to 20A
1J1027
1J1027
The 1027 fixture is used with 6565 dc bias units to mount conventional DIL devices for testing up to 40A
1J1028
1J1028
The 1028 fixture is used with 6565 dc bias units to mount conventional DIL devices for testing up to 60A
1J1031
1J1031
The 1031 adaptor is used with 1026, 1027 or 1028 fixtures to allow 2-terminal connections to bottom contact surface mount devices for testing up to 60A.
1J1037
1J1037
The 1037 Adaptor provides SMA interface connectivity from a 6565 to a remote test head, such as a SMD taping machine
1J10264
1J10264
The 10264 fixture is used with 6565 dc bias units to allow 4-terminal connections to bottom contact surface mount devices for testing up to 20A
1J10284
1J10284
The 10284 fixture is used with 6565 dc bias units to allow 4-terminal connections to bottom contact surface mount devices for testing up to 60A
FACTORY VIEW
FACTORY VIEW
MESCO VIEW
MESCO VIEW

Wayne Kerr Electronics jest producentem precyzyjnych urządzeń pomiarowych, uznanym za lidera w swojej dziedzinie i rozpoznawanym za jakość, dokładność i szerokie możliwości swoich urządzeń. Wayne Kerr rozpoczął działalność w roku 1946, w Londynie w Wielkiej Brytanii. W ciągu ostatnich 60 lat firma Wayne Kerr Electronics stała się wiodącym producentem urządzeń do procesów testowych (mierniki LCR, analizatory impedancji, wysokiej częstotliwości analizatory LCR). Zapewnia wsparcie techniczne i serwis swoich urządzeń klientom na całym świecie. W celu usprawnienia obsługi i wsparcia technicznego na polskim rynku firma Wayne Kerr Electronics utworzyła autoryzowany oddział firmy. Poza tym posiada swoje oddziłay na całym swiecie, w kilku krajach Europy, w Stanach Zjednoczonych, Singapurze, Indiach, Japonii, Chinach i na Tajwanie.

adres

Adres:

ul. Lotnicza 108, 80-297 Banino k. Gdańska

telefon

telefon:

+48/58-742-11-27

mail

e-mail:

office@waynekerr.pl