Overview

The 6500B series of Precision Impedance Analyzers provide precise and fast testing of components at frequencies up to 120 MHz. Basic measurement accuracy is ±0.05% making the instruments the best in the class.

The accuracy and versatility makes the precision analyzers the ideal choice for many different tasks and applications including passive component design, dielectric material characterisation and manufacturing test.

Engineers need to evaluate component characteristics at high frequencies with high levels of accuracy. The 65120B 120 MHz Precision Impedance Analyzer is therefore ideal for many demanding tasks, combining accuracy and ease of use at an affordable price. If a frequency range up to 120 MHz is not required then other models are available. The 6505B 5MHz instrument is the entry level model in the range.

High measurement accuracy

Capacitance, inductance and impedance basic accuracy is an excellent ±0.05%. Dissipation factor accuracy is ±0.0005 and the quality factor accuracy is ±0.05%.

Graphical sweep of components

The 6500B series of Precision Impedance Analyzers are highly accurate high frequency component analyzers with a host of useful features.

Graphical sweep of two measured parameters is available and displayed on the clear, large, colour display. Swept parameters are frequency, drive level and DC bias.

Display formats available include series or parallel equivalent circuit.

An Equivalent Circuit Anlysis function is available . This allows modelling and curve fitting to various equivalent circuit models. Four types of three component and a four component model are available. The instrument will calculate the nearest equivalent circuit parameters for the measurement traces and revise the results. Alternatively the component parameters may be entered and the instrument will plot the frequency characteristics.

For single frequency measurements a meter mode is available.

Analysis Mode Meter Mode Complex Mode

Option feature - Polar and Complex Plots & Multi Measurement Mode

Polar and Complex Plots  Polar and Complex Plots

Variable drive and bias levels

AC drive levels up to 1V or 20mA can be selected to evaluate components in realistic operating environments.

The /D1 DC bias option provides 0 to +40V dc bias voltage and 0 to +100mA dc bias current while the /D2 option provides -40V to +40V dc bias voltage.

External control

The GPIB interface is used to control the instrument and read back measured values for applications such as quality control or for archiving purposes.

An Ethernet interface similarly allows the instrument to be controlled and to send out data - allowing it to be integrated into many test environments.

Wide range of interfaces

An external monitor or projector may be connected to the instrument. The ability to provide a large screen display is invaluable in production environments or for teaching and training.

Instrument control from both a keyboard and mouse is available. Any keyboard or mouse, with either PS/2 or USB interfaces, can be simply connected to provide an alternative method of instrument control and operation.

Data storage and retrieval

All measurement and setup data can be stored using the Ethernet interface or a USB flash memory (supplied as standard).

Setup data

Up to 20 instrument setups may be stored locally for each mode.

Bin handling

The /B1 option (non-isolated 5V) or /B2 option (isolated 24V) signals are available through a 25-way D-type connector. 10 bins can be set using absolute or percentage limits.

Printer outputs

Hard copy printouts can be obtained in a number of ways including direct to an HP-PCL compatible graphics printer or Epson compatible text/ticket printer. A networked HP-PCL compatible printer may also be used via Ethernet connection.

Component connections

Four front panel BNC connectors permit three or four terminal connections with the screens at ground potential.

The 1J1011 component fixture, supplied as standard, ensures optimum performance when measuring a wide range of components of leaded components and devices.

1J1012 (2 Terminal) and 1J1014 (4 Terminal) fixtures allow connection to surface mount devices.

Protection against charged capacitors

High precision measuring instruments can be damaged by charged capacitors which can cause costly repairs and unacceptable downtime. All the models in the range incorporate protection against charged capacitors.

Comprehensive and precise component tests at higher frequencies

The 6500B series capabilities are best summarised by "Comprehensive and precise component tests at higher frequencies". The instruments are the perfect solution for those who have demanding component measurement needs.

Najważniejsze Parametry​

  • Precyzyjne pomiary impedancji wysokiej częstotliwości
  • Charakterystyka komponentów od 5 do 120 MHz
  • Szeroka gama modeli o maksymalnych częstotliwościach od 5 MHz (6505 B) do 120 MHz (65120 B)
  • 0,05% podstawowa dokładność pomiaru
  • Napięcie polaryzacji DC 0 do + 40 V i polaryzacji prądu DC 0 do 100 mA (opcja)
  • Napięcie polaryzacji ± 40 V DC (opcja)
  • Kompleksowe funkcje pomiarowe
  • Łatwy w użyciu dzięki dużemu ekranowi dotykowemu TFT
  • Precyzyjne wyświetlacze graficzne pomagają w odczycie wyników pomiarów
  • Tradycyjny tryb miernika LCR dla pojedynczych i cyklicznych pomiarów
  • Wyszukiwanie rezonansowe
  • Analiza obwodu równoważnego (opcja)
  • Intuicyjny interfejs użytkownika
  • W pełni programowalny przez GPIB i LAN
  • Dostępne rysowanie przebiegów biegunowych POLAR i złożonych COMPLEX PLOTS (opcja)
  • Dostępny tryb seryjnych pomiarów Multi Measurement Mode (opcja) 
  • Opcjonalne sterowanie za pomocą klawiatury i myszy
  • Konkurencyjne ceny

Technical Specification

Measurement Function Capacitance (C) 
Inductance (L)
Resistance (R)
Reactance (X)
Conductance (G)
Susceptance (B)
Dissipation Factor (D)
Quality Factor (Q)
Impedance (Z)
Admittance (Y)
Phase Angle (Ø)
Frequency Range 6505B 20Hz to 5MHz
6510B 20Hz to 10MHz
6515B 20Hz to 15MHz
6520B 20Hz to 20MHz
6530B 20Hz to 30MHz
6550B 20Hz to 50MHz
65120B 20Hz to 120MHz

Frequency step size 0.1 mHz
Accuracy of set frequency ±0.005"%
AC Drive Level 10 mV to 1V rms (varies with frequency)
200 µA to 20 mA rms (varies with frequency)
Measurement Speeds 4 speeds selectable 
Up to 20 measurements per second for test frequencies ≧100 Hz
Accuracy Dissipation factor - ±0.0005 (1+D2)
Quality factor - ±0.05 %( Q+1/Q)
Capacitance / Inductance / Impedance - ±0.05%
Accuracy varies with frequency, drive level and measured impedance
DC Bias Current (Option) /D1 0 to +100mA dc bias current and 0 to +40V dc bias voltage 
/D2 -40V to +40V dc bias voltage
Binning (Option) 10 bins with absolute and percentage limits 
25 way d-type interface connector
/B1 (Non-isolated) Comon 0V Bin outputs 0 to 5V(normal) with >10mA current sink capability
/B2 (isolated) Comon 24V input outputs 0 to 24V with >10mA current source capability
Input Specification Power supply - Input voltage 90 V AC to 264 V AC (Autoranging)
Mains frequency 47 to 63 Hz
Display 8.4" VGA (640 x 480) color TFT with touch panel
Measurement Connections Four front panel BNC connectors permit two, three or four terminal connections with the screens at ground potential.
1J1011 Component Fixture (supplied as standard) allows connection to leaded components and devices.
Printer HP-PCL compatible graphics printing (local and network) 
Centronics / parallel printer port, Epson compatible text/ticket printing (local)
Remote Trigger Rear panel BNC with internal pull-up, operates on logic low or contact closure
GPIB Interface External instrument control 24 pin IEEE 488 connector
USB Interface Two Unversal Serial Bus (USB) interfaces
USB 1.1 compliant
VGA Interface 15-way D-type connector to drive an external monitor in addition to the internal screen
Network Interface 10/100-BASETX Ethernet controller
RJ45 connector
Keyboard Interface Standard USB or PS/2 keyboard port. Instrument front panel remains active with keyboard plugged in
Mouse Interface Standard USB or PS/2 mouse port
Touch screen remains enabled when the mouse is connected

6500P SERIES
6500P SERIES
The 6500P series of high frequency LCR meters include extended test frequency capability, high accuracy and a large high resolution color display
6565 SERIES
6565 SERIES
To evaluate components at currents up to 60 A, the 6565 DC Bias Units are used with the Wayne Kerr 6500B and 6500p models of precision analyzers
6400 SERIES
6400 SERIES
Provide thorough and accurate testing of any passive component to market-leading accuracy
4300 SERIES
4300 SERIES
A range of easy to use LCR meters with comprehensive measurement functions.
Accurate and fast measurements may be made from 20Hz to 1MHz (43100) making the 4300 series the ideal choice for many applications in the test or production environment
3265B SERIES
3265B SERIES
To evaluate components at high currents the 3265B/25A DC Bias Units may be used with either the Wayne Kerr 3255B Inductance Analyzer or the 3260B Precision Magnetics Analyzer. Bias current may be set from 25mA to 25A in steps of 25mA
3260B SERIES
3260B SERIES
Offers all measurement parameters needed for the analysis of magnetic components up to 3MHz including true 4-terminal primary to secondary parameters by using 8 front panel BNC
3255B SERIES
3255B SERIES
Highly versatile and accurate inductance analyzers able to characterise devices in a clear and simple manner
1EV1006
1EV1006
Remote test fixture for axial, radial or bandoliered components. Complete with cable terminating in four BNC connectors
1EV1505
1EV1505
600 mm extension cable terminated with four BNC connectors at the instrument end and four individual crocodile clips at the component end.
1EV1905A
1EV1905A
The 1905A ead with two sprung needle probes is used to access surface mounted devices on circuit boards and for interfacing to hybrid components and chip components on tape.
1EV1905X
1EV1905X
The 1905X is a 4-2 BNC converter plus lead with two sprung needle probes to access surface mounted devices on circuit boards and for interfacing to hybrid components and chip components on tape.
1EVA40100
1EVA40100
Wayne Kerr Kelvin Clips consist of a 0.6 m cable assembly terminated with four BNC connectors at the analyzer end and a pair of 4-terminal Kelvin clips at the Device Under Test end.
1EVA40120
1EVA40120
Chip component tweezers for contacting leadless devices. The cable is terminated with BNC connectors.
1EVA40150
1EVA40150
The 40150 is a price sensitive version of 1EVA40100 Fine Jaw Kelvin Clips for use with 4300 series LCR Meters
1EVA40180
1EVA40180
600mm extension cable terminated with four BNC connectors at the instrument end and a pair of large jawed Kelvin clips at the component end.
1EVA40125
1EVA40125
1J1001
1J1001
The 1J1001 4 to 1 BNC Converter is used to connect a Wayne Kerr 6500 analyzer to the Device Under Test using a single BNC connector. This is useful when the connection terminal of the DUT is a single BNC, such as some antennas. The outer of the single BNC is isolated.
1J1002
1J1002
The 1012 fixture makes a 2-terminal measurement to end contact surface mount devices and is suitable for medium and high impedance devices.
1J1011
1J1011
1J1012 SMD 2
1J1012 SMD 2
The 1012 fixture makes a 2-terminal measurement to end contact surface mount devices and is suitable for medium and high impedance devices.
1J1014 SMD 4
1J1014 SMD 4
The 1014 fixture makes a 4-terminal measurement to end contact surface mount devices and is especially suitable for low impedance devices.
1J1020
1J1020
The 1020 Fixture is used with the 6500 series, and when used with the /K Materials Test firmware option allows the permittivity of the Material Under Test (MUT) to be calculated automatically.It allows both the Contacting Electrode and the Non-contacting Electrode Methods to be used up to a maximum frequency of 30 MHz.
1J1022
1J1022
The 1J1022 Liquid Fixture is used to make accurate dielectric constant and impedance measurements of liquid materials. When used with a Wayne Kerr 6500 analyzer then the 1J1002 4-2 BNC Converter (available separately) must also be used.
1J1023
1J1023
The 1023 adaptor allows 2-terminal accessories to be used with 4-terminal analyzers, such as the 4300 and 6500, which do not have a 2 Term/ 4 Term switching facility on their front panel.
1J1025
1J1025
The 1025 probe allows a 6500 to make ground referenced impedance measurements. In normal use the 6500 is unable to measure components which have one terminal directly referenced to ground, but the 1025 Probe is the solution to this restriction.
1J1026
1J1026
The 1026 fixture is used with 6565 dc bias units to mount conventional DIL devices for testing up to 20A
1J1027
1J1027
The 1027 fixture is used with 6565 dc bias units to mount conventional DIL devices for testing up to 40A
1J1028
1J1028
The 1028 fixture is used with 6565 dc bias units to mount conventional DIL devices for testing up to 60A
1J10264
1J10264
The 10264 fixture is used with 6565 dc bias units to allow 4-terminal connections to bottom contact surface mount devices for testing up to 20A
1J10284
1J10284
The 10284 fixture is used with 6565 dc bias units to allow 4-terminal connections to bottom contact surface mount devices for testing up to 60A
1J10324
1J10324
The 10324 fixture makes a 4-terminal measurement to bottom contact surface mount devices and is especially suitable for low impedance devices.
5-654-7010
5-654-7010
The 7010 Transfer Standard Kit consists of conventional body transfer standards which must be used when extension cables or different fixtures (to the 1011 supplied with the unit) are used with a 6500. They allow the open circuit, short circuit and HF compensation routines to be performed.
5-654-7011
5-654-7011
The 7011 Transfer Standard Kit consists of surface mount component transfer standards which must be used when extension cables or different fixtures (to the 1011 supplied with the unit) are used with a 6500. They allow the open circuit, short circuit and HF compensation routines to be performed.
5-654-7012
5-654-7012
The 7012 terminator kit must be used with fixtures which do not have the 6500 terminating components built into them. The kit consists of 4 BNC female to male adaptors.
5-654-7013
5-654-7013
The 7013 terminator kit must be used with fixtures which do not have the 6500 terminating components built into them. The kit consists of 4 BNC female to female adaptors.
FACTORY VIEW
FACTORY VIEW
MESCO VIEW
MESCO VIEW

Wayne Kerr Electronics jest producentem precyzyjnych urządzeń pomiarowych, uznanym za lidera w swojej dziedzinie i rozpoznawanym za jakość, dokładność i szerokie możliwości swoich urządzeń. Wayne Kerr rozpoczął działalność w roku 1946, w Londynie w Wielkiej Brytanii. W ciągu ostatnich 60 lat firma Wayne Kerr Electronics stała się wiodącym producentem urządzeń do procesów testowych (mierniki LCR, analizatory impedancji, wysokiej częstotliwości analizatory LCR). Zapewnia wsparcie techniczne i serwis swoich urządzeń klientom na całym świecie. W celu usprawnienia obsługi i wsparcia technicznego na polskim rynku firma Wayne Kerr Electronics utworzyła autoryzowany oddział firmy. Poza tym posiada swoje oddziłay na całym swiecie, w kilku krajach Europy, w Stanach Zjednoczonych, Singapurze, Indiach, Japonii, Chinach i na Tajwanie.

adres

Adres:

ul. Lotnicza 108, 80-297 Banino k. Gdańska

telefon

telefon:

+48/58-742-11-27

mail

e-mail:

office@waynekerr.pl